Welding Electrode

ROYAL – 8018 C1 (E 8018-C 1)

E 8018-C 1

AWS : SFA 5.5, E 8018-C 1 EN ISO 2560 A E 46 6 2Ni B 32 H5

Applications

It is used for welding of nickel alloy piping, System valves and tanks. Used for welding low temperature service for Locomotive main frames, Refeneries, Pipelines.

Welding Positions

1G 2F 3G 4G

Notes On Usage

1) Dry the electrodes at 250 -300°C
2) Preheat at 80 – 100°C
3) Keep the arc as short as possible .

Chemical Composition Of Weld Metal

C% Mn% Si% S% P% Ni%
0.12 Max 1.25 Max 0.80 Max 0.030 Max 0.030 Max 2.0 – 3.75

Mechanical Properties Of Weld Metal

U.T.S.(N/mm²) Y.S.(N/mm²) ELONGATION ( L = 4d ) % RADIOGRPHY TEST Hydrogen(Mercury method) in 100grm weld metal IMPACT ( CVN )AT – 60 °C ( J )
550 Min 460 Min 19 % Min Satisfactory 4 ml Max 27 Joules Min

Packing and Welding Current

SIZE ( mm ) KG PER PACKET KG PER CARTON Current (Amps) In Amps
2.50 X 350 5 20 AC/DC (+) 60 – 90
3.15 X 350 5 20 100-140
4.00 X 350 5 20 140-180
5.00 X 350 5 20 180-250

Related Products

1) Redry electrode at 250 °C for 2 hours. Keep the arc as short as possible.
AWS : A / SFA 5.11, E Ni Cu - 7 EN ISO 1472 A E Ni 4060
AWS A/SFA 5.15, Est. EN ISO 1071 A EC Fe 1 3

Share On:

Enquiry form

Contact Form